Avigilon Unity / ACC - Dynamic Integration

AvigilonLogo.png

Native Integration Available

This is SureView integration requires a Class 2 License and a Device Server. Please contact your account manager for more details.

 

 

Supported Features

  • Live Video
  • PreAlarm Recording
  • Camera Playback
  • Playback
  • PTZ (Pan / Tilt / Zoom)
  • Preset GoTo
    Note: Avigilon Presets start from 0
  • Quality Control
  • Output 
    Important:  PULSE will trigger Output ON  Only. Outputs cannot be turned OFF from Sureview.
  • Get Configuration
  • Sync 

Requirements

Package Requirements

The following packages will be deployed by your SureView Engineer

  • CC-DEVICE-DynamicIntegration-1.5.2.4200 (or above)
  • CC-DEVICE-AvigilonControlCenterDynamicIntegration-1.5.2.5936 (or above)

Version Requirements

Validated against Avigilon Control Center 8.4.1.4

Note: The Avigilon Dynamic integration uses the Avigilon API to connect (instead of the Avigilon SDK)

Manufacture License Requirements

N/A - No additional manufacturer license required

Network Requirements

From To Port Description
Sureview OpsLink Server / Device Server(s) ACC Web Endpoint (Avigilon Server) 8443 by default Login, sync, PTZ, outputs, and live and recorded video 
Avigilon Control Center Server us.sureviewops.com / eu.sureviewops.com 443 HTTP Alarms (SureView Response / SaaS)
Note: alarms are not currently supported but will be added in a future release.

 

SureView Device Setup

 

Sync Configuration

Using the SureView Advanced Device Setup go to the Sync Tab and add "Avigilon Dynamic" as a new Sync System including the following fields

Host The server running the ACC Web Endpoint. (The Avigilon Server)
Port 8443 by default. This is set in the Web Endpoint configuration on the ACC server.
Username Your Avigilon Username
Password Your Avigilon Password
Extra value 
 
Leave Blank

Native Integration: Area Sync

Once you have saved your Sync Configuration (described above) you can then add the individual Area Syncs to synchronise Avigilon against individual Areas in Sure View.

  1. Go to the  Sureview "Syncs" tab (when adding or editing your Sync System)
  2. Click Add Area Sync
  3. Complete the Area Sync Fields
Field Value
Title The friendly name for the Area Sync
Area Which SureView Area should the sync use when adding doors/alarms etc
Identifier

Enter the "site" or "server" filter you want to use to match your Avigilon cameras

Examples

site:MainOffice
server:Server01

 

This should match the name of the site or server in the Avigilon interface (Site is the most common filter option to use)

Interval How often should the system sync into SureView?
default: 24 hours
Enabled

Enable or Disable the automatic Sync

default on

Allow Update Area Allows the sync to automatically move synced doors/alarms to a different area

Default off

recommended to keep off
Allow update Device Settings

Allows the sync to automatically update the door/alarm settings

Default off

 

recommended to keep off

 

Cameras

Camera fields will be automatically populated by Get Config / Sync

Title The camera name in ACC. Renaming it in ACC will update the title on the next sync
Input1 The position in ACC's full camera list for the site
Input2 -1 (Not used)
Extra Value The WEP camera ID. This is only used by the API and is not visible in the ACC client

Important: Get Config / Sync does not set camera PTZ or Presets. These will need to be enabled manually in the sureview Device Setup - Camera Setup screen

Outputs

Important:  PULSE will trigger Output ON  Only. Outputs cannot be turned OFF from Sureview.

Output fields will be automatically populated by Get Config / Sync

Title The Output name in ACC. Renaming it in ACC will update the title on the next sync
Input1 The position in ACC's full output list for the site
Input2 -1 (Not used)
Extra Value The WEP output ID. This is only used by the API and is not visible in the ACC client

 

Alarm Points

Alarm point fields will be automatically populated by Get Config / Sync however these are not currently in use. Full alarming functionality is planned for a future integration release.

Title

The name of the alarm in ACC. If this is empty SureView uses the following: 

<deviceName> input <n>

Input1 The position in ACC's full input list, similar to a camera's Input1
Input2 -1 (Not Used)
Extra Value The WEP entity ID. This is only used by the API and is not visible in the ACC client