Native Integration Available
This is SureView integration requires a Class 2 License and a Device Server. Please contact your account manager for more details.
Supported Features
- Live Video
- PreAlarm Recording
- Camera Playback
- Playback
- PTZ (Pan / Tilt / Zoom)
- Preset GoTo
Note: Avigilon Presets start from 0 - Quality Control
- Output
Important: PULSE will trigger Output ON Only. Outputs cannot be turned OFF from Sureview. - Get Configuration
- Sync
Requirements
Package Requirements
The following packages will be deployed by your SureView Engineer
- CC-DEVICE-DynamicIntegration-1.5.2.4200 (or above)
- CC-DEVICE-AvigilonControlCenterDynamicIntegration-1.5.2.5936 (or above)
Version Requirements
Validated against Avigilon Control Center 8.4.1.4
Note: The Avigilon Dynamic integration uses the Avigilon API to connect (instead of the Avigilon SDK)
Manufacture License Requirements
N/A - No additional manufacturer license required
Network Requirements
| From | To | Port | Description |
| Sureview OpsLink Server / Device Server(s) | ACC Web Endpoint (Avigilon Server) | 8443 by default | Login, sync, PTZ, outputs, and live and recorded video |
| Avigilon Control Center Server | us.sureviewops.com / eu.sureviewops.com | 443 | HTTP Alarms (SureView Response / SaaS) Note: alarms are not currently supported but will be added in a future release. |
SureView Device Setup
Sync Configuration
Using the SureView Advanced Device Setup go to the Sync Tab and add "Avigilon Dynamic" as a new Sync System including the following fields
| Host | The server running the ACC Web Endpoint. (The Avigilon Server) |
| Port | 8443 by default. This is set in the Web Endpoint configuration on the ACC server. |
| Username | Your Avigilon Username |
| Password | Your Avigilon Password |
|
Extra value |
Leave Blank |
Native Integration: Area Sync
Once you have saved your Sync Configuration (described above) you can then add the individual Area Syncs to synchronise Avigilon against individual Areas in Sure View.
- Go to the Sureview "Syncs" tab (when adding or editing your Sync System)
- Click Add Area Sync
- Complete the Area Sync Fields
| Field | Value |
| Title | The friendly name for the Area Sync |
| Area | Which SureView Area should the sync use when adding doors/alarms etc |
| Identifier |
Enter the "site" or "server" filter you want to use to match your Avigilon cameras Examples site:MainOffice
This should match the name of the site or server in the Avigilon interface (Site is the most common filter option to use) |
| Interval | How often should the system sync into SureView? default: 24 hours |
| Enabled |
Enable or Disable the automatic Sync default on |
| Allow Update Area | Allows the sync to automatically move synced doors/alarms to a different area Default off recommended to keep off |
| Allow update Device Settings |
Allows the sync to automatically update the door/alarm settings
recommended to keep off |
Cameras
Camera fields will be automatically populated by Get Config / Sync
| Title | The camera name in ACC. Renaming it in ACC will update the title on the next sync |
| Input1 | The position in ACC's full camera list for the site |
| Input2 | -1 (Not used) |
| Extra Value | The WEP camera ID. This is only used by the API and is not visible in the ACC client |
Important: Get Config / Sync does not set camera PTZ or Presets. These will need to be enabled manually in the sureview Device Setup - Camera Setup screen
Outputs
Important: PULSE will trigger Output ON Only. Outputs cannot be turned OFF from Sureview.
Output fields will be automatically populated by Get Config / Sync
| Title | The Output name in ACC. Renaming it in ACC will update the title on the next sync |
| Input1 | The position in ACC's full output list for the site |
| Input2 | -1 (Not used) |
| Extra Value | The WEP output ID. This is only used by the API and is not visible in the ACC client |
Alarm Points
Alarm point fields will be automatically populated by Get Config / Sync however these are not currently in use. Full alarming functionality is planned for a future integration release.
| Title |
The name of the alarm in ACC. If this is empty SureView uses the following: <deviceName> input <n> |
| Input1 | The position in ACC's full input list, similar to a camera's Input1 |
| Input2 | -1 (Not Used) |
| Extra Value | The WEP entity ID. This is only used by the API and is not visible in the ACC client |
Comments
0 commentsPlease sign in to leave a comment.