The following is a camera integration that utilises the SureView Standards Based Integrations and is included as part of all SureView Response Subscriptions
Introduction
The Camect Smart Camera Hub solves the problem of alert fatigue by filtering out useless information caused by bugs, animals, shadows, weather and more. At the same time Camect empowers professional and self-monitoring by elevating useful alerts about people, in places they shouldn't be
Camect Alarm Features
- Bulk Alarm Import
- ResponseCode Matching
- EventType Matching
- Attached Alarm Video
Requirements
Camect Hub with a Camect Pro Monitoring License
(Talk to your Camect representative if you don't already have this license)
First Time Configuration
Create the SureView Standard Decoder
This decoder is usually pre-configured in your SureView Account. These instructions are here in case it needs to be added manually or edited. Please contact SureView Support before making changes to the Standard Decoder
- Login to SureView and navigate to the "Alarms" setup screen
- Click on the "Alarm Decoder" Tab
- If the "SureView Standard Decoder" does not already exist:
Click "Add Alarm Decoder" and complete the following values
Title: SureView Standard Decoder SureViewResponseCode:\s*(?<rc>[^\r\n]+)
Event Regex SureViewEventTypeCode:\s*(?<ec>[^\r\n]+)
Default Area: Select your top level area
(Your SureView Organisation Account Name)Default Action Plan: Select your preferred Action Plan or leave blank Default Grouping: Select your preferred Default Grouping
Recommended "By Area"Default Priority Enter your preferred default priority
Recommended: 100
Add the Camect Event Types
These Event Types are normally pre-configured in your SureView Account. These instructions are here in case it needs to be added manually or edited. Please contact SureView Support before making changes to the Standard Decoder
- Login to SureView and navigate to the "Alarms" setup screen
- Click on the "Alarm Decoder" Tab
- Edit the "SureView Standard Decoder"
- If the following Event Types don't already exist - Add them
Note: The Event Type Name, Default Priority and Default Grouping can be customised to your requirements but the "Event Code" must match exactly (including case) for compatibility with Camect
Event Type Name Event Code Default Priority Default Grouping InputAlarm InputAlarm 100 Inherit TamperAlarm TamperAlarm 100 Inherit ObjectDetected ObjectDetected 100 Inherit DevicePowerup DevicePowerup 100 Inherit DeviceShutdown DeviceShutdown 100 Inherit HDDFull HDDFull 100 Inherit DeviceDisarm DeviceDisarm 100 Inherit
Camect Hub - Alarm Configuration
In SureView
- Login to SureView and go to Alarm Setup
- Click on the "Alarm Decoder" tab
- Note down your unique "SureView Standard Decoder" email address. by:
- Open Notepad (or another note taking application)
- Copy the "System Identifier" from SureView and paste it into notepad (it will look something like t3p45bc4gr)
- add it to as a prefix to SureView region / web address to make the email address. It should look something like t3p45bc4gr@us.sureviewops.com or t3p45bc4gr@eu.sureviewops.com
- This is the email address you will use in your Camect Hubs
In Camect
- Login to Camect using Chrome and navigate to their "V2 UI"
- Click the Settings button on the Camect Hub you wish to configure
- Click on the Alerts Tab
- Configure your detection settings as required
- Click the "Add monitoring" button and select "sureview" from the list
- Select your SureView Response region (US or EU)
-
Enter your unique SureView Email Address that you noted down when following the steps above
- Click Download setup.csv
- Enter the exact name (case sensitive) of the SureView Area (site) you want to add Camect to and press OK
In SureView
- Login to SureView and go to Alarm Setup
- Click BULK ADD
- Upload the setup.csv you downloaded from Camect
- Customise any rows as required
- Press Add
Done. You have now configured your Camect hub to send alarms into SureView.