NX Witness

Have more questions? Submit a request

Native Integration Available

This integration requires a Class 2 License and is available for SureView Enterprise (On-Premises) and SureView Response (SaaS). Please contact your account manager for more details.

 

 

Native Integration: Supported Features

  • Get Configuration
  • Live Video
  • Camera Playback
  • PreAlarm Recording
  • PTZ
  • Presets
    Note: PTZ Preset compatibility depends on individual NX Witness NVRs. SureView can't guarantee compatibility across all NX Witness cameras and settings
  • Alarms
    Sureview Enterprise (On Premises): SMTP/Email Alarms
    Sureview Response (SaaS): HTTPS Alarms

     

Native Integration: Requirements

 

SureView Package Requirements

The following packages will be deployed by your SureView Engineer

  • SMTPReceiver (SureView Enterprise On-Premises Only)
  • CC-DEVICE-DynamicIntegration
  • CC-DEVICE-DigitalWatchdogDynamicIntegration
    Note: The package is named "Digital Watchdog" but does install both the Digital Watchdog and NX Witness Device Types as they share common components.

Version Requirements

Tested against NX Witness  6.1.2.42921
Note: This is not a hard version requirement, this is the version that the integration was tested against

 

License Requirements

N/A - No manufacturer license required

 

Network Requirements

From To Port Description
OpsLink / Sureview Device Server NX Witness 7001 API Port
Video & Device Commands
NX Witness Device Server
(SMTP Receiver) 
25 SMTP Alarms (Sureview Enterprise / On-Premises)
NX Witness us.sureviewops.com / eu.sureviewops.com 443 HTTP Alarms (SureView Response / SaaS)

The port settings can be found by:

  1. Logging in using the NX Witness Client
  2. Right click on the Server and click "Server Settings"
  3. Open the "General" tab to see the "Port" field

2026-11-06 12_59_50-lab-nxwitness.northeurope.cloudapp.azure.com - Remote Desktop Connection Manager.png
 

Permission Requirements

  • Live View
  • View Archive
  • User Input

Note: These are the minimum required permissions

User Permissions can be configured on the NX Witness by logging in using the client software and:

Create the User Group for SureView

  1. Open System Administration (right click on the home icon in the NX Witness menu or press Ctrl+Shift+A)
  2. Go to User Management tab
  3. Click "Add Group" to created a dedicated Sureview user group
  4. Enter the group name "Sureview"
  5. Go to "Resources" tab
  6. Ensure that at a minimum "Live View", "View Archive" and "User Input" are ticked for all cameras
  7. Press Add Group
2026-11-06 13_02_33-lab-nxwitness.northeurope.cloudapp.azure.com - Remote Desktop Connection Manager.png

Create the User for Sureview

  1. Open System Administration (right click on the home icon in the NX menu or press Ctrl+Shift+A)
  2. Go to User Management tab
  3. Go to the "Users" tab
  4. Click "Add User"
  5. Provide a secure Username and Password for Sureview to use to connect to cameras  (Leave "Allow insecure" unticked)
  6. Select the sureview permission group that you created earlier
  7. Press Add User
2026-11-06 13_04_16-lab-nxwitness.northeurope.cloudapp.azure.com - Remote Desktop Connection Manager.png

 

Camera Stream Requirements

Camera streams must be set to H.264 

Camera Stream settings can be configured in the NX Witness Client:

  1. Login to the NX Witness Client Software
  2. Expand the Server in the side bar
  3. Right click on the individual camera and select "Camera Settings"
  4. Go to the "Advanced tab"
  5. Ensure both the Primary Codec and Secondary Codec is set to H.264
    (Primary Codec is used for High / Highest Quality and Secondary Codec is used for Lowest / Low / Medium quality settings in SureView)
     

To validate the stream codec and resolution you can start playing the Live Camera in the NX Witness client and hover the cursor over the camera window. The codec information in the bottom left corner of the screen

Native Integration: Device Setup

Field Value
Title The user facing name of the NX Witness system you are connecting to
Area The Area/Site that the cameras and Alarms will be added to. 
Type NX Witness
OpsLink (If using SureView Response) The name of your connected OpsLink+ Server 
Host The local IP of your NX Witness (from the perspective of the Device Server) 
Port The NX Witness  port (7001 by default)
Configuration / ExtraValue

leave blank

 

 

Once the device details have been added use Get Configuration to auto populate the Cameras and Alarms

Native Integration: Setup Live Camera Streaming

Camera detail will be automatically populated by Get Configuration feature

Field Value
Title
The name of the camera that will be shown to the operator
Area The Area/Site the camera will be associated with
Input1 auto incremented camera number (not related to the device itself)
Input2 Not used, leave as "-1"
ExtraValue

NX Witness Camera ID - auto populated by Get Config. This is the unique identifier used to connect to the specific camera. 

 

NX Witness Camera ID

To find the Camera ID manually, login to the NX Witness client software...

  1. Expand the Server in the left-hand side bar
  2. right click on the individual camera and select "Camera Settings"
  3. go to the "General tab"
  4. Click "More Info" drop down to expand and show more info
  5. Camera ID is displayed here (with a copy option) 
    2026-11-06 13_06_35-lab-nxwitness.northeurope.cloudapp.azure.com - Remote Desktop Connection Manager.png

 

Native Integration: Setup Email Alarms (Sureview Enterprise)

Initial SMTP Setup

Configure NX Witness to use your SureView Enterprise Server as the SMTP Server

  1. Open the Site Administration screen in NX Witness
  2. Click the Email Tab
  3. set your SMTP Server address as your SureView Server host address (where your  Sureview SMTP Receiver service is hosted).  Include the port number in the address e.g. myserver:25

Configuring alarm points
Alarm Points will be automatically added in SureView by Get Configuration or Sync with one alarm point per NX Witness camera. 

  1. Make a note of your Device number (ServerID) for your NX Witness device. You can find this when editing the device in SureView Device Setup
    2026-01-16 16_34_05-SureView — Mozilla Firefox Private Browsing.png
     
  2. Login to the NX Witness Client
  3. Go to the individual camera you want to configure an alarm  for - right click and select "Camera Rules"
  4. Click "Add" to add a camera rule and enter the following details
    1. Event
      1. When: Select the action to trigger the alarm such as "Motion on Camera"
      2. At: Select the individual camera you are configuring or ALL Cameras)
    2. Action:
      1. Do: Send Email
      2. To: Leave this blank
      3. Additional Recipients: Add the S#@sureviewalarms.com replacing the # with the Server/Device ID found in Sureview the previous steps
      4. Interval of action: Set at a low figure to ensure no missed alarms
      5. Press OK
  5. Repeat for each  alarm trigger you want to send into SureView
  6. Press OK once complete. NX Witness is now configured to send alarms into SureView

 

 

Native Integration: Setup HTTP Alarms (Sureview Response / SaaS)

Once your NX Witness device(s) are set up, you'll need to contact SureView Support to have them enabled to receive alarms.

  1. Raise a support ticket listing the Device Title(s) and Device ID(s) (shown on the Device Information Setup page) for each device you want configured for alarming.

This requires a data request to be completed on our backend systems, which typically takes between 5 and 15 working days depending on demand. We'd recommend raising this ticket in good time before you need alarming to be live. 

 

Configuring NX Witness

  1. Open NX Witness
  2. Right click on a camera in the camera tree and click "Camera Rules"
  3. Click Add Rule
  4. Give the Rule a name such as "Sureview Motion Alarm"
  5. In the "WHEN" section, select the triggering condition and camera such as 
    Motion on Camera Occurs At: Any Camera
  6. In the "DO Action" section select HTTP(S) Request and then fill in the following details
     
  7. URL

    https://{region}.sureviewops.com/receiver/{DeviceIdentifier}


    Example
    https://us.sureviewops.com/receiver/5cfacc02-7379-48fe-a745-689161010e7a

    Method Post
    Custom Headers Key: X-Api-Key
    Value: Your Sureview HTTP Alarm API Key
    (You can find your API Key in Sureview by going to "Alarm Setup" then the "HTTP Alarms" tab then copying the key)
    Content

    {"type":"motion","time":"{event.time}","caption":"{event.caption}","desc":"{event.description}","deviceId":"{device.id}","deviceName":"{device.name}","site":"{site.name}"}

     

    Change motion to whatever type of alarm you are using. This will be used as the matching Event Code which can be configured in Event Type Setup. 

    Content Type application/json
    Authentication Auto
    Login / Password leave blank
    Interval of Action Set to your preferred option (how frequently can the alarm trigger)
  8. Press OK

2026-11-13 11_33_05-lab-nxwitnes.png
 

Alarm Event Types

The following NX Witness Alarm Event Types can be decoded by default:

Title Event Code
Motion motion
Input input
Vehicle vehicle
Person person

 

 

Troubleshooting

Preset GoTo not working

Unfortunately we have found that occasionally a camera's PTZ Presets won't be compatible with SureView. We cannot guarantee compatibility with all NX Witness camera Presets

HTTP Alarms not being received

  1. Ensure that the NX Witness has network access to us.sureviewops.com / eu.sureviewops.com port 443
  2. Ensure the HTTP URL is correct (check the DeviceID)
  3. Ensure the Sureview API Key entered in the custom header is correct

 

 